Extreme Weather Screw Assembly
Hot Dip Galvanized - Category 4
Drive Type: Hex 3/8
Base Material Thickness : 0.75-5.00mm Steel
One piece washer assembly for both Corrugated and Square Rib Roofing Sheet profiles
DESIGN CRITERIA
Products conform to the structural requirements of the National Construction Code Series (NCC) and the relevant Australian Standards:
- AS 1562.1 – 1992 (R2016 amdt. 1 – 1993, amdt. 2 1995, amdt. 2012 Design and installion of sheet roof and wall cladding
- AS 4040 – 1992 – Methods of testing sheet roof and wall cladding
Part 0: Introduction, list of methods and general requirements
Method 3: Methods of testing sheet roof and wall cladding – Resistance to wind pressures for cyclone regions, pressure test regime as per BCA Low-HighLow pressure sequence.
CORRUGATED ROOF SHEETING (0.42mm BMT) – LYSAGHT
Screw Assembly: ICCONS Cyclonix®
14-10x55mm SDS Hex Class 4
Part No.: SDHXTG14055C4X
Purlin Type: C1501.5 1.5mm thick
Test Reference Number: C140202-1
Screw Assembly: ICCONS Cyclonix
14-13x57mm Hex SDS Class 4
Part No: SDHXUNI1457C4X
Supports: 0.75mm BMT G550 top hat battens
Test Reference number: TS1230
TRIMDEK ROOF SHEETING
(0.42mm BMT) – LYSAGHT
Screw Assembly: ICCONS Cyclonix®
14-10x55mm SDS Hex Class 4
Part No.: SDHXTG14055C4X
Purlin Type: C1501.5 1.5mm thick
Test Reference Number: C140202-2
Screw Assembly: ICCONS Cyclonix
14-13x57mm Hex SDS Class 4
Part No: SDHXUNI1457C4X
Supports: 0.75mm BMT G550 top hat battens
Test Reference number: TS1231
ALL TESTED IN ACCORDANCE WITH THE ABOVE STANDARDS AND DEEMED TO MEET ALL REQUIREMENTS.